EN
Routine inspection business
2019.07.23

 

 Number Detection object Number Test item
 1 Fixed low temperature insulation pressure vessel 1 Effective volume
 2 Sealing vacuum
 3 Cold vacuum
 4 Air leakage rate
 5 Leakage rate
 6 Static evaporation rate
 7 Macro inspection
 8 Ultrasonic testing
 9 Magnetic particle inspection
 10 Penetration test
 11 Wall thickness measurement
 12 Pressure/air tightness test
 2 Cryogenic liquid car/railway tank car 1 Effective volume
 2 Sealing vacuum
 3 Cold vacuum
 4 Air leakage rate
 5 Leakage rate
 6 Static evaporation rate
 7 Pressure/air tightness test
 8 Macro inspection
 9 Wall thickness measurement
 10 Ground resistance
 11 Ultrasonic testing
 12 Radiographic inspection
 13 Magnetic particle inspection
 14 Penetration test
 3 Cryogenic liquid tank container 1 Effective volume
 2 Sealing vacuum
 3 Cold vacuum
 4 Air leakage rate
 5 Leakage rate
 6 Static evaporation rate
 7 Hold time
 8 Pressure/air tightness test
 9 Macro inspection
 10  Wall thickness measurement
 11 Ground resistance
 12 Ultrasonic testing
 13 Radiographic inspection
 14 Magnetic particle inspection
 15 Penetration test
 4 Cryogenic insulated gas cylinder 1 Vacuum Degree
 1 Air leakage rate
 2 Leakage rate
 3 Static evaporation rate
 4 Heat leakage
 5 Withstand voltage test
 6 Macro inspection
 5 Low temperature insulated pipe 1 Vacuum Degree
 2  Air leakage rate
 3  Static evaporation rate
 4  Heat leakage
 5  Withstand voltage test
 6 Macro inspection
 6 Cryogenic valves (low temperature gate valves, globe valves, check valves, ball valves, butterfly valves) 1 Low temperature sealing performance
 2 Cold action
 3 Low temperature impact performance
 7 Safety valve 1 Nominal diameter
 2 Runner diameter
 3 Nominal pressure
 4 Set pressure
 5 Rated discharge pressure
 6 Opening height
 7 Rated displacement
 8 Opening and closing pressure difference
 8 Rupture disk 1 Geometric size
 2 Sealing performance
 3 Burst pressure
 4 Burst pressure tolerance
 5 Discharge volume
 6 Flow resistance coefficient
 7 stress test
 9 Emergency shut-off valve 1 Mechanical properties of valve body
 2 Low temperature impact performance
 3 Shell strength
 4 Penetration test
 5 Leak test
 6 Air tightness test
 7 Action test
 8 Natural closure test
 9 Vibration test
 10 Minimum wall thickness of valve body
 10 Thermal conductivity of cryogenic container materials and internal support materials 1 Thermal Conductivity
 11 Thermal insulation material for cryogenic containers (expanded perlite) 1  Loose/vibration density
 2Loose/vibration density
 3 granularity
 4 Mass moisture content
 5Angle of repose
 6 Equivalent thermal conductivity
 12Multilayer insulation material  1 Thermal Conductivity
 2 Apparent thermal conductivity
 3 Deflation rate
 4 Temperature resistance
 5 compatibility
 6tensile strength
 13 Adsorption material for vacuum container 1 Adsorption capacity
 2 Specific surface area
 3 The average particle size
 4 Pore size distribution
 14 Air bath vaporizer 1 Weld quality
 2 Gasification
 3 Pressure/air pressure test

 


            
Zip Code: 528251
Tel: 0757-66860226
Fax: 0757-66860225